10kVA Scalable to 90kVA Modular UPS
Features
Specifications
Applications
Download
-
• Rackdesign
Modular design, compatible with 19” standard rack cabinet, convenient to integrated with servers
• Flexible configuration
The system can be configured to 1/1 and 3/1 without derating or hardware changing
• High power density
10/15kVA power module in 2U height Saving great amount of space, easy for capacity expansion
• Friendly interface
7” touch color LCD with graphic display, more information displayed for customereasier for customer to operate
• Integrated solution for data center
UPS can integrate with battery cabinet and PDU, offering excellent choice for data center
• Smart sleep function
System can intelligently shutdown some power modules to increase total load rate, achieving higher efficiency
• Intelligent charging management
The system intelligently control the whole process of the charging and discharging, effectively improve life time of the battery
• Self-agingmode
Energy internal circle technology, system can run with full load, assuming less than 10% energy
Read More -
Model RM060/10X RM040/10X RM020/10X RM090/15X RM045/15X RM030/15X System capacity 60KVA 40KVA 20KVA 90KVA 45KVA 30KVA Power Module Capacity 10KVA/10KW 15KVA/15KW Input Dual Input Standard Phase 3 Phase +Neutral +Ground,380V/400V/415(line-line) Input Voltage Range 228-304VAC(line-line)load, decreases linearly according to the min phase voltage Rate Frequency 50/60Hz Input Frequency Range 40Hz-70Hz Input PF >0.99 Input THDI <4%(100% Linear load) Bypass Rate Voltage 380/400/415Vac(line-line) Rate Frequency 50/60Hz Input Voltage Range Settable,-40%-+25% Bypass Frequency Range Settable, ±1Hz, +3Hz, ±5Hz Bypass Overload 110% long term operation; 125% for 5 min;150% for 1s; 110% long term operation; 130% for 5 min;150% for 1mins >150% for 300ms; Output Rate Voltage 380/400/415Vac (line-line) Voltage Regulation 1%for balance load 1.5% for unbalance load Rate Frequency 50/60Hz Frequency Precision 0.10% Output PF 1 Output THDU <1%,Linear load ;<5.5%,Non-Linear load Crest factor 3:1 Inverter Overload 110% for 1 hour;125%for 10 mins;150%for I min >150% for 200ms Battery Voltage ±240Vdc Battery Number 40pcs (settable:even number form 32 to 44) Voltage Precison ±1% Change Power up to 20% Output active power Battery Cold Start Optional System Efficiency AC Mode 95% ECO Mode 98% Battery Mode 94.50% Display 7.0'color touch screen LCD + LED + keyboard I P Class IP20 Interface RS232, RS485, Programmable Dry Contact Option PDU for RM150/25CSNMP Card, Parallel kit, SPD, LBS Temperature Operation:0 ~ 40°C Storge: -40 ~ 70 °C Relative Humidity 0 - 95% Non-condensing Altitude <1000m. Within 1000m to 2000m, 1% power derating for every 100m rise Noise (1 meter) 56dB @ 100% load Applicable Standards Safety: IEC/EN 62040-1 BMC:IEC/EN 62040-2 Performance: IEC/EN 62040 Physical Weight(kg) Cabinet 70 51 42 70 55 42 Power module 15.3 15.5 Dimension W*D*H(mm) Cabinet 486*761*1033 486*697*676 486*697*398 486*8761*1033 486*761*676 486*697*398 Power module 436*590*85 Read More -
Read More
-
Read More
Contact Us
24 hours online, to ensure your after-sales worry.