MaisonProduits5G Base Station Power Supply Outdoor 48V Rectifie
  • Alimentation électrique 5G
  • Alimentation électrique 5G

5G Base Station Power Supply Outdoor 48V Rectifie

90 - 300Vac ; Rectifier: 48V / 3 - 6kW
Overviews
The SY 5G Base Station Power Supply is a highly integrated outdoor power cabinet that combines AC input power distribution, lightning protection, switching rectification, battery packs, DC output power distribution, Field Supervision Unit (FSU), and an outdoor chassis. Its system monitoring module is powerful, covering battery management and power system monitoring. It can achieve environmental monitoring through sensors and provides multiple sets of backup monitoring quantities. The RS485 communication interface lays the foundation for remote monitoring and unattended operation.
  • Features

  • Specifications

  • Applications

  • Télécharger

The battery management is meticulous, with complete LVLD + LVBD functions, including temperature compensation, automatic equalization and floating charge control, voltage regulation, capacity calculation, and online testing, comprehensively ensuring stable and long-lasting battery performance.
The communication interface is diverse and the lightning protection design is comprehensive. The RS485/dry contact interface combined with the lightning protection on the AC and DC sides in thunderstorm areas ensures safe communication in severe weather conditions.
The optional APP for remote meter reading function allows users to easily control the power consumption data at any time, facilitating efficient energy management.
The built-in wireless monitoring unit supports NB-IOT access to the user’s monitoring network, greatly improving the efficiency of remote operation and maintenance and equipment management and control capabilities.

The diverse indoor and outdoor designs meet the requirements of various scenarios, precisely adapting to both urban indoor and remote outdoor base stations.
The integrated structure simplifies the installation process, saves space resources, reduces construction costs and floor space, and improves space utilization.
The modular architecture covering the power supply, battery, power distribution, and cooling systems enables convenient and efficient installation and maintenance. In case of a malfunction, the modules can be quickly replaced, shortening the downtime and enhancing the convenience and overall efficiency of operation and maintenance.

Read More
Configuration Type Configuration Parameters
Maximum Output Power 2KW/3KW 6KW
Input Voltage Range 90 - 300 Vca 90 - 300 Vca
Output Rated Voltage 53.5V 53.5V
Output Rated Current 56A 112A
Rectifier (or Main Board) 48V - 3000W * 1 48V - 6000W * 1
AC Input 1 circuit 60A/3P 1 circuit 40A Fuse
DC Output 7 circuits 40A/2P 3 circuits 40A Fuse
Battery Input 2 circuits 125A/2P, capable of connecting 2 sets of 48V 50Ah lithium batteries 1 circuit 60A Fuse, capable of connecting 1 set of 48V 50Ah lithium batteries
Expansion Parallel Interface Can be shared with output interface and battery interface Can be shared with output interface and battery interface
Communication Interface There are 2 circuits in total, namely DB15 and DB9 1 circuit with 16 signal ports.
DB15: 1 circuit RS485 north port, 1 circuit CAN parallel communication port, 1 circuit reserved CAN communication port, 1 circuit LAN port communication Actual configuration: 1 circuit RS485 north port, 1 circuit CAN parallel communication port, 1 circuit reserved CAN communication port
DB9: 3 output dry nodes (power failure, input power failure, battery failure) 3 output dry nodes (power failure, input power failure, battery failure)
Indicator Light There are 3 (normal (green) / failure (red) / alarm) (yellow) There are 3 (normal (green) / failure (red) / alarm) (yellow)
Monitoring Interface 1) The power equipment has a built-in wireless monitoring unit, which can access the mobile monitoring network in the form of full-network access (4G standard). 2) Locally wirelessly connect with existing mainstream smartphones to display monitoring content. 1) The power equipment has a built-in wireless monitoring unit, which can access the mobile monitoring network in the form of full-network access (4G standard). 2) Locally wirelessly connect with existing mainstream smartphones to display monitoring content.
Environmental Monitoring AGN1 - FSU * 1 AGN1 - FSU * 1
Lithium Iron Battery V - LFP4850 * 2 V - LFP4850 * 1
Installation Method Wall-mounted and pole-mounted Wall-mounted, pole-mounted and flag-mounted
External Dimensions 348W * 450H * 144D (mm) 320W * 420H * 70D (mm)
Weight Power supply: 20.4KG, Lithium iron battery 48V 50AH: 34.58KG 9.84kg