Advanced Rackmount High Frequency UPS
Features
Specifications
Applications
Télécharger
-
• True double-conversion
• Output power factor 1
• Output voltage regulation < 1%
• Higher output crest ratio 3:1
• 50Hz/60Hz frequency converter mode, Programmable power management outlets, Emergency power off function (EPO), Hot swappable battery design
• ECO mode energy saving
• Emergency power off (EPO) function.
• Provides over voltage cut-off protection and surge immunity by MOV for full time equipment protection.
• High power factor charger up to 1000W capacity with very low ripple current when charging battery.
• Low input THDi to reduce power system pollution*Adjustable charging current via LCD panel
Read More -
MODEL SYRT1K SYRT 1.5K SYRT 2K SYRT 3K PHASE Single phase with ground CAPACITY* 1000 VA/1000W 1500 VA/1500W 2000 VA/2000 W 3000 VA/3000W INPUT Nominal Voltage 100/110/115/120/127 VAC or 200/208/220/230/240 VAC Voltage Range 55-150 VAC±5% or 110-300 VAC±5% @50% load
80-150 VAC±5% or 160-300 VAC±5%@100% loadFrequency Range 40 Hz ~ 70 Hz Power Factor ≧ 0.99 @ nominal voltage (100% load) Harmonic Distortion(THDi) ≦5%@ nominal input voltage OUTPUT Output Voltage 100*/110*/115*/120/127 VAC or 200*/208*/220/230/240 VAC AC Voltage Regulation (Batt. Mode) ±1% Frequency Range (Synchronized Range) 57~ 63 Hz or 47~ 53 Hz Frequency Range(Batt. Mode) 60Hz±0.1Hz or 50 Hz±0.1Hz Current Crest Ratio 3:1(max.) Harmonic Distortion ≦2%THD (Linear Load);≦4% THD (Non-linear Load) Transfer
TimeAC Mode to Batt. Mode Zero Inverter to Bypass 4m s (Typical) Waveform(Batt. Mode) Pure Sinewave EFFICIENCY AC Mode ≧89% @ full charged battery ≧91% @ full charged battery ECO Mode ≧96% @ full charged battery Battery Mode ≧88% ≧90% BATTERY Battery Type 12V/9 Ah 12 V/7Ah 12V/9Ah 12 V/9Ah 12VI7 Ah 12 V/9Ah Numbers 2 3 3 4 6 6 Typical Recharge Time 3 hours recover to 95% capacity for internal battery@ 2A charging current Charging Current 100/110/115/120/127 VAC models: default 2A, max.8A adjustable
200/208/220/230/240 VAC models: default 2A, max.12A adjustableDefault: 2A, Max: 8A adjustable Charging Voltage 27.4 VDC ±1% 41.1 VDC±1% 41.1 VDC ±1% 54.8VDC±1% 82.1 VDC ±1% 82.1 VDC ±1% INDICATORS LCD Display UPS status, Load level, Battery level, Input/ Output voltage, Discharge timer, and Fault conditions ALARM Battery Mode Sounding every 5 seconds Low Battery Sounding every 2 seconds Overload Sounding every second Fault Continuously sounding PHYSICAL Dimension,DxWxH(mm) 410×438×88 410×438×88 510×438×88 630×438×88 630×438×88 Net Weight(without battery) (kgs) 6.6 7.8 8.1 9.4 10.6 12.4 Net Weight (w/ built-int battery) (kgs) 11.6 14.1 15.5 19.5 23.3 27.5 ENVIRONMENT Humidity 20-90% RH@0 - 40℃ (non-condensing) Noise Level Less than 50dB @1 Meter Altitude 10% de-rating for over 1000m(The altitude should not exceed 3000m) MANAGEMENT Smar t RS-232/USB Supports Windows2000/2003/XP/ Vista/2008/7/8/10, Linux and MAC Optional SNMP Power management from SNMP manager and web browser STANDARD EMC/ safety (EMC 1-1.5K:EN62040-2C1,2K-3K EN62040-2 C2) for CE models * Derate capacity to 80% when the output voltage is adjusted to 100VAC/200VAC/208VAC.
Product specifications are subject to change without further noticeMODEL SY 6K(L) RT SY 10K(L) RT PHASE 1 phase in/1 phase out CAPACITY* 6000 VA/6000W 10000 VA/10000W INPUT Nominal Voltage 208/220/230/240 VAC Voltage Range 110~300VAC±3% at 50% load
176~300VAC±3 % at 100% loadFrequency Range 46~54 Hz ◎50Hz/56~64 Hz◎60Hz Power Factor ≧ 0.99 @ full load THDi <4% @100% Load,<6%@50% Load OUTPUT Output Voltage 208*/220/230/240 VAC 208*/220/230/240 VAC AC Voltage Regulation ±1% Frequency Range (Synchronized Range) 46~54 Hz ◎50Hz/56~64 Hz◎60Hz Frequency Range (Batt. Mode) 50 Hz±0.1 Hz or 60 Hz±0.1 Hz Current Crest Ratio 3:1(max.) Harmonic Distortion ≦1% THD (Linear Load),≦4% THD(Non-linear Load) Transfer
TimeAC Mode to Batt. Mode Zero Inverter to Bypass Zero Waveform(Batt. Mode) Pure Sinewave Overload AC Mode 100%~110%:10min、110%~130%: 1min >130%:1sec Battery Mode 100%~110%:30sec ·110%~130%:10sec>130%:1sec EFFICIENCY AC Mode 94% 94% ECO Mode 98.5% 98.5% Battery Mode 92% 92% BATTERY Standard
ModelBattery Type 12VI7AH 12V19AH Numbers 16 20 16 20 Typical Recharge Time 9 hours recover to 90% capacity Charging Current (max.) 1.0A Charging Voltage 218.4 VDC±1% 273 VDC±1% 218.4 VDC±1% 273 VDC ±1% Battery Type Depending on applications Long-run
ModelNumbers 16-20** Charging Current (max.) 4.0A Charging Voltage (13.65VDCx battery number) ±1% INDICATORS LCD Panel UPS status, Load level, Battery level, Input/ Output voltage, Discharge timer, and Fault conditions ALARM Battery Mode Sounding every 4 seconds Low Battery Sounding every second Overload Sounding twice every second Fault Continuously sounding PHYSICAL Standard
unitDimension,DxWxH(mm) UPS Unit: 610×438×88[2U]
Battery Pack:715×438 ×88[2U]UPS Unit:610×438×88 [2U]
Battery Pack:600×438× 133[3U]UPS Unit:610×438×88[2U]
Battery Pack:715×438×88[2U]UPS Unit:610×438×88[2U]
Battery Pack:600 ×438×133[3U]Net Weight (kgs) UPS Unit: 17
Battery Pack:48UPS Unit: 17
Battery Pack: 57UPS Unit: 20
Battery Pack:53UPS Unit: 20
Battery Pack:63Long-backup
unitDimension,Dx WxH(mm) 610×438×88[2U] 610×438×88[2U] Net Weight(kgs) 17 20 ENVIRONMENT Operating Humidity 20-90 % RH @0 - 40℃(non-condensing) Noise Level Less than 55dB @ 1 Meter Less than 58dB @ 1 Meter MANAGEMENT Smart RS-232/ USB Supports Windows⑧2000/2003/XP/ Vista/2008,Windows⑧7/8/10, Linux and MAC Optional SNMP Power management from SNMP manager and web browser * Derate capacity to 60% of capacity in CVCF mode and to 90% when the output voltage is adjusted to 208VAC or paralle system is operated.
* When using 16 pieces of batteries, the output power factor will be derated to 0.8. If using 18 or 19 pieces of batteries, the output power factor will be derated to 0.9
If the UPS is installed or used in a place where the altitude is above than 1000m, the output power must be derated one percent per 100m.
Product specifications are subject to change without further notice.Model SYRT 20 kVA SYRT 30 kVA SYRT 40 kVA SYRT 60kVA Phase 3-phase in and 3-phase out Capacity 20kVA/20kW 30 kVA/30 kW 40 kVA/40 kW 60 kVA/60 kW Parallel capacity 4max Input Rated voltage 3x380VAC(3PH+N) Voltage range 190-520 VAC (3 phase) @50% load. -305-478VAC (three-phase)@100% load Frequency range 46 ~ 54Hz or 56 ~ 64Hz Power factor ≥0.99 100% load Output Rated voltage 3×360*/380/400/415 VAC(3PH+N) Output accuracy (battery mode) ±1% Frequency range (synchronous correction range) 46 ~ 54Hz or 56 ~ 64Hz Frequency range (battery mode) 50 Hz±0.1 Hz or 60 Hz±0.1 Hz Current wave front ratio 3:1 (maximum) Harmonic distortion ≤1%THD (linear load) ≤3%THD (nonlinear load) Conversion time Mains mode to battery mode none Inverter to bypass none Waveform (battery mode) pure sine wave Overload Mains power mode 100-110%60 minutes·110-125%10 minutes·125%-150%1 minute; >150% immediate protection battery mode 100-110%60 minutes·110-125%10 minutes·125%-150%1 minute; >150% immediate protection Efficiency Mains power mode 95.5% ECO mode 98.5% Battery mode 94.5% Batterie Battery Type Match multiple battery boxes according to actual application Quantity 32~40 (adjustable) Maximum charging current 1A ~ 12A (adjustable) 1A~16A (adjustable) 1A~18A (adjustable) Charging voltage ±13.65VxN(N=16 ~ 20) Physical properties Dimensions, depth × width × height (mm) 680×438×133[3U] 797×438×176(4U) Net weight (kg) 30 32 40 45 Usage environment Temperature and humidity 0-95% relative humidity (non-condensing) and temperature 0-40℃ Noise Less than 65dB@1 meter Less than 70dB@1 meter Control management Smart RS-232/USB Supports Windows·Series·Linux and MAC OptionalSNMP Power management supports SNMP management and network management *When the output voltage is set to 3x360VAC, the output capacity is derated to 90%. Product specifications are subject to change without prior notice.