Metered PDU Monitoring Power Distribution

AC 1/3-phase ; DC 48V/240V/336V
Overviews
Intelligent PDU can achieve real-time monitoring of the data center, inside the cabinet and all kinds of terminal equipment of current and voltage feedback, to help operation and maintenance personnel adjust the working state of all kinds of equipment, to provide first-hand information for personnel to understand the demand for data center energy statusandmeet the requirements of energy saving, safety and it reduce the cost of operation and maintenance.
  • Features

  • Specifications

  • Applications

  • Télécharger

F1:Total monitoring
F2:Total monitoring+Unit monitoring
F3:Total monitoring+Unit control
F4:Total monitoring+Unit control+Unit monitoring

Remote access
Support ModbusRTU

Monitoring
Remote monitoring PDU total(loop/packet) current,voltage,power,electric energy, power factor
Remote monitoring of each output unit current,voltage,electric energy, power, power factor(F2/F4)
Monitor the temperature and humidity inside the cabinet、access control、smoke、water leakage、and infrared environment through an external sensor

Control and configuration
Remote control of each output unit, output unit state maintained(F3/F4)
User-defined the sequential power-on and power-off delay. the output unit is powered on and off periodically((F4))
User-defined the total current and voltage threshold. The current of each output unit can be defined by F2, F4

Read More
Smart F series PDU Parameters
Input Input Type AC single phase, AC three phase,-48VDC,240VDC,336VDC
Input Mode Transparent open type junction box,power cord, cable, industrial connector, socket etc.
Input Voltage Range 100-277VAC/312VAC-418VAC/100VDC-240VDC/-43VDC- -56VDC
AC Input Frequency 50/60Hz
Total Load Current MAX63A
Output Storage Temperature -40℃~+70℃
Relative Humidity 5~95%(No condensation)
Atmospheric Pressure 70 kPa~106 kPa
Working Altitude No more than4000m
Environme ntal Working Temperature -10℃~+75℃
Storage Temperature -40℃~+80℃
Relative Humidity 5~95%(No condensation)
Working Altitude No more than3000m
IP Rating IP20
Protection Input Protection Module Circuit breaker, lightning protection, leakage protector, temperature insepction module (optional)
Output Protection Module Circuit breaker, fuse box, fuse(optional)
Read More
  • Communication industry
  • Security system
  • IDC engine room
  • Electric power system
  • Track traffic
  • Enterprise small and medium data center
  • Office scene
  • Dispatch center

Read More
Read More

Contactez-nous

24 hours online, to ensure your after-sales worry.

Veuillez activer JavaScript dans votre navigateur pour remplir ce formulaire.
WhatsApp

Laissez un message!

Laissez un message!

Veuillez activer JavaScript dans votre navigateur pour remplir ce formulaire.