MaisonProduitsAlimentation UPSOnduleur haute fréquenceRack-Mounted 0.8 PF High Frequency UPS
  • High-Frequency UPS Rack Mounted
  • High-Frequency UPS Rack Mounted

Rack-Mounted 0.8 PF High Frequency UPS

Power Factor: 0.8 ; 208/220/230/240Vac
Overviews
Standard rack-mounted structure design, compatible with tower installation. 110V to 300V wide input power range, adaptable to harsh power grid environment. Zero conversion time between AC mode and battery mode. Input zero live wire detection function. With voltage surge protection function and strong anti-interference function. Output power factor 0.8, stronger load capacity.
  • Features

  • Specifications

  • Applications

  • Télécharger

Realize online double conversion

Microprocessor control technology ensures high reliability input power factor correction

Output power factor 0.8

Wide input voltage (110V to 300V)

Efficient frequency conversion mode

ECO mode provides energy saving effect (only for 1-3K models compatible with generator input

Long-term backup charging current up to 6A

Read More
Model SYRT 1kVA SYRT 2KVA SYRT 3KVA SYRT 6KVA SYRT 10KVA
Phase single phase grounded
Capacity 1000VA/800W 2000VA/1600W 3000VA/2400W 6000VA/4800W 10000VA/8000W
Iutput
Rated voltage 100/110/115/120/127VAC or 200/208/220/230/240VAC 208/220/230/240VAC
Voltage range 55-145VAC or 110-300VAC at 50% load
85-140VAC or 160-280VAC at 100% load
110-300 VAC±3% at 50% load
176-300VAC±3% at 100% load
Frequency range 40Hz~70Hz 46Hz~54 Hz or 56Hz~64 Hz
Power factor ≧0.99@100% load
Output
Rated voltage 100/110/115/120/127VAC or 200/208/220/230/240VAC 208/220/230/240VAC
Voltage range (battery mode) ±1% ±1%
Frequency range (synchronous correction range) 47~53 Hz or 57~63 Hz 46Hz~54 Hz or 56Hz~64 Hz
Frequency range (battery mode) 50Hz±0.25Hz or 60Hz±0.3Hz 50Hz±0.1Hz or 60Hz±0.1Hz
Current wave front ratio 3:1
Harmonic distortion ≦3%THD (linear load); ≦5%THD (nonlinear load) ≦3%THD (linear load); ≦5%THD (nonlinear load)
Conversion time Mains mode to battery mode none
Inverter to bypass 4 milliseconds (under standard conditions) 0 milliseconds
Waveform (battery mode) pure sine wave
Efficiency
Mains power mode 88% 89% 90% 92% 93%
Battery mode 83% 87% 88% 90% 91%
Batterie
Standard unit Battery Type 12V/9AH 12V/9AH 12V/9AH 12V/9AH
Quantity 2 4 6 16 pieces 20 pieces 16 pieces 20 pieces
Standard charging time Charge to 90% in 4 hours Charge to 90% in 9 hours
Maximum charging current 1.0A (maximum) Default: 1.0 A, Max.: 2.0A
Charging voltage 27.4VDC±1% 54.7VDC±1% 82.1 VDC±1% 218.4VDC±1% 273VDC±1% 218.4VDC±1% 273VDC±1%
Long backup unit Battery Type Match multiple battery boxes according to actual application
quantity 2 3 4 6 6 8 16~20(adjustable)
Maximum charging current 1.0A/2.0A/4.0A/6.0A 1A/2A/4A/6A (adjustable, 6A is only suitable for 16 batteries)
Charging voltage 27.4VDC±1% 41.0VDC±1% 54.7VDC±1% 82.1 VDC±1% 82.1 VDC±1% 109.4VDC±1% 218.4VDC±1% (based on 16 pcs)
Display Instructions
LCD or LED display Load size, battery capacity, mains mode, battery mode, bypass mode, fault indication
Warning sound
Battery mode Beeps every 4 seconds
Battery low One sound every 1 second
Overload One sound every 1 second
Fault Continuous beeping
Physical Properties
Standard machine Dimensions, depth × width × height (mm) 310×438×88[2U] 410×438×88[2U] 630×438×88[2U] Host: 530x438x88[2U] Battery Kit: 668x438x88[2U] Host: 530x438x88[2U] Battery Kit: 580×438×133 [2U] Host: 580x438x133[3U]
Battery kit: 580x438x133[3U]
Net weight (kg) 12 19 29.3 Host: 15
Battery Kit: 48
Host: 15
Battery Kit: 61
Host: 18 Battery Kit: 51 Host: 18 Battery Kit: 61
Long lasting machine Dimensions, depth × width × height (mm) 310×438×88[2U] 410×438×88 [2U] 500×438×88[2U] 580×438×133 [3U]
Net weight (kg) 9 12 14.2 15 18
Usage Environment
Temperature and humidity Relative humidity 20-90% and temperature 0-40°C (no condensation) Relative humidity 0-95% and temperature 0-40°C (non-condensation)
Noise Less than 50dBA@1 meter Less than 55dBA@1m Less than 58dBA@1m
Control Management
Intelligent RS-232/optional USB Support Windows*2000/2003/XP/ Vista/2008, Windows*7/8, Linux, Unix, and MAC
Optional SNMP Power management supports SNMP management and network management
*When the UPS is set to constant voltage and constant frequency mode, the output power will be reduced by 40%. When the output voltage of the UPS is set to 208VAC, the output power will be reduced by 10%. **When the number of internal batteries is changed to 16-19, the machine will reduce the output according to the following formula: P=PratingX(N/20×100%). ***If the machine is installed at an altitude of more than 1000 meters, the output power will be reduced by 1% for every 100M increase. The current product specifications are subject to change without further notice.