OverviewsAir-cooled row-level Inverter compressor Precision air conditioner, seamlessly compatible with enclosed and open cabinets, efficient and energy-saving, is the ideal choice for cooling micro module data centers.
• Safe and Reliable Key components such as compressors, fans and controllers all adopt top brands in the industry, with a Mean Time Between Failures (MTBF) of no less than 100,000 hours.
The expert-level precision air conditioner control system comes standard with a 7-inch touch screen and a graphical interface. It can display parameters such as temperature and humidity in the form of curves, supports remote monitoring and management, and has the function of automatic startup upon power restoration.
• Low-Carbon and Energy-Saving There are options for fixed-frequency and variable-frequency refrigeration systems available, with remarkable energy-saving effects.
The indoor fan adopts a backward-inclined centrifugal EC fan, which can automatically and steplessly adjust the air volume according to the refrigeration requirements, achieving high efficiency, energy conservation and low noise.
A large-area V-shaped evaporator is adopted to optimize the air flow organization and enable efficient heat exchange.
• Flexible Application It supports top air supply, bottom air supply (with the fan sunk), front-top air supply and duct air supply.
The electric control box is installed with drawer-type slide rails, facilitating service and maintenance.
Optional accessories such as low-temperature components, pipeline extension components, condensate pumps, water leakage monitoring devices, dual power supplies and V-shaped condensers are available to support special application scenarios.
• Support for Customization It offers flexible and comprehensive customization services, supporting customized unit performance, external dimensions and appearance design, etc.
Read More
Indoor Unit
007RA
012RA
017RA
020RA
025RA
030RA
040RA
050RA
065RA
075RA
090RA
Total Cooling-kW
7.5
12.6
17.8
25.5
31.5
41.5
50.5
75.5
21.5
65.5
90.5
SHR-%
100
100
100
100
100
100
100
100
100
100
100
Air Volume-m³/h
2300
2500
4500
4920
5100
6000
8100
10200
12100
13600
16200
Mount Type
Row
Row
Row
Row
Row
Row
Row
Row
Row
Row
Row
Cooling Type
DX
DX
DX
DX
DX
DX
DX
DX
DX
DX
DX
Height-mm
2000
2000
2000
2000
2000
2000
2000
2000
2000
2000
2000
Depth-mm
1100
1100
1100
1100
1100
1100
1100
1100
1100
1100
1100
Width-mm
300
300
300
300
300
300
600
600
600
900
900
Weight-kg
213
233
253
258
260
320
360
420
460
540
620
Reheat-kW
3.0
3.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
Hum.(optional)-kg/h
1.5
1.5
1.5
1.5
1.5
3
3
3
3
3
3
Power Input1)
208-240V
/50-60Hz
/1Ph-2Ph
208-240V
/50-60Hz
/1Ph-2Ph
380-415V
/50-60Hz
/3Ph
380-415V
/50-60Hz
/3Ph
380-415V
/50-60Hz
/3Ph
380-415V
/50-60Hz
/3Ph
380-415V
/50-60Hz
/3Ph
380-415V
/50-60Hz
/3Ph
380-415V
/50-60Hz
/3Ph
380-415V
/50-60Hz
/3Ph
380-415V
/50-60Hz
/3Ph
FLA-A1)with heating
37.3
48.7
27.0
26.7
27.9
34.6
37.7
48.1
60.6
70.8
84.6
FLA-A1)with hum.
42.4
53.8
32.1
31.8
33.0
39.7
47.9
58.3
70.8
81.0
94.8
Power Input 2)
-
380-415V
/50-60Hz
/3Ph
200-230V
/50-60Hz
/3Ph
200-230V
/50-60Hz
/3Ph
200-230V
/50-60Hz
/3Ph
200-230V
/50-60Hz
/3Ph
200-230V
/50-60Hz
/3Ph
-
-
-
-
FLA-A2)with heating
-
20.9
49.4
48.8
51.1
63.2
68.9
-
-
-
-
FLA-A2)with hum.
-
22.0
52.5
52.0
54.2
66.4
75.1
-
-
-
-
Power Input 3)
-
-
460V
/60Hz
/3Ph
460V
/60Hz
/3Ph
460V
/60Hz
/3Ph
460V
/60Hz
/3Ph
460V
/60Hz
/3Ph
460V
/60Hz
/3Ph
460V
/60Hz
/3Ph
460V
/60Hz
/3Ph
460V
/60Hz
/3Ph
FLA-A3)with heating
-
-
22.3
22.1
23.1
28.6
31.1
39.7
50.1
58.5
69.9
FLA-A3)with hum.
-
-
26.5
26.3
27.3
32.8
39.6
48.2
58.6
66.9
78.4
Standard Outdoor
Unit Model
KSF12AN
KSF18AN
KSF24AN
KSF32AN
KSF38AN
KSF42AN
KSF52AN
KSF62AN
KSF85AN
KSF52AN
KSF62AN
Unit Qty
1
1
1
1
1
1
1
1
1
2
2
Notes: 1. Air flow is based upon standard fan speed setting. Fan modulates per real loads. 2. Cooling Capacity based on 37℃/24%RH return air and 45℃ condensing temperature. 3. FLA of indoor unit includes FLA of outdoor unit, and outdoor unit power connected from indoor unit. 4. SNMP monitoring port, dual power input, and leaking detection are optional. 5. Standard unit works -15℃ above outdoor temperature, select low temperature kit to run for -35C outdoor ambient temperature.