Industrial Frequency Durable UPS 160-600kVA

Power Factor: 0.9 ; 160 - 600kVA
Overviews
SY-G Series is a high end 3 Phase Input/ Output transformer based UPS system. It adapts the innovative designing concept of integration. It also has significantly improved the efficiency and reliability. Product Performance Index has reached international level. With Multiple Digital Control Modules, such as DSP, MCU, and CPLD, SY-G can be non-prioritized paralleled up to 8 units to lower operating costs without compromising reliability, performance, and availability.
  • Features

  • Specifications

  • Applications

  • Download

  • Advanced Rectifier and IGBT Technology:Features advanced rectifier and IGBT technology. Input THDI≤4%, Input Power Factor≥0.99 to save more energy. With optional filters, input power factor can be upto >0.99 and THDI<4.5%.
  • Wide Input Characteristics:Has a wide input voltage range, high adaptive capacity, and good generator – compatibility.
  • Load – related Performance:Exhibits high load compatibility, short – circuit protection, and high overload ability. Output Power Factor is 0.9 without lagging.
  • Fault Detection:Can self – evaluate and alarm in case of phase misconnection or loss.
  • Full – digitized Control:The RP – N series uses full – digitized control for all power conversion sections during operations, enhancing system reliability.
  • Cooling System Design:Features internal parallel redundancy design for cooling fans.
  • Output Transformer:Has a built – in output isolated transformer to reduce impacts and interferences from load harmonic wave current and N – wire voltage.
  • Component Quality:90% of system components are from international brands. All devices are aged and tested for 24 hours before leaving the factory.
  • Communication Interfaces:Integrates multiple communication interfaces like RS232, RS485, dry contact, and EPO. Optional SNMP communication adapter is available.
  • Maintenance and Connection:Adopts front – maintenance design and is available for top connections with protection devices.
  • User Interface:Features an intuitive user interface with a large dot – matrix LCD screen and a multi – functional keyboard.
Read More
Model RP1600L33-N RP2000L33-N RP2500L33-N RP3000L33-N RP4000L33-N RP5000L33-N RP6000L33-N
Capacity 160KVA/144KW 200KVA/180KW 250KVA/225KW 300KVA/270KW 400KVA/360KW 500KVA/450KW 600KVA/540KW
Host Machine Specification
UPS Structure Online Double Conversion
Appearance Low Frequency with Output Isolated Transformer
Overall Efficiency (AC-AC) 94%(With Optional Accessories)
ECO 98%
Noise (In 2 Meters) 67dB
Working Temp. 0-40℃
Storage Temp. -15 ~ 50℃( without batteries)
Humidity < 95% Non-Condensing
National Standard IEC60950-1,IEC62040-1-1
International Standard IEC62040-2,IEC62040-3
Parallel Redundancy Parallel Redundancy Upto 8 Units
Protection Overload, Short-Circuit, Over Temp., Utility Power Voltage High/low, BAT Voltage High/low
DC Start Available
Generator Compatibility Available
Display LCD Display(Multi-Language with all kinds of messages)+LED
Mute Auto
Cabinet Standard IP20
Cooling System Intelligent Speed Control Cooling Fan
Elevation <1500M, Without Derated
Rectifier Specification
Input Voltage 380/400/415Vac+N+W (3 phase + PE)
Input Voltage Range 298-498Vac
Input Frequency Range 50/60Hz±10%
Soft-Start 5-600 Seconds, Adjustable
Input PF 0.95(With Optional Input Wave Filter)
THDI < 5%( With Optional Accessories)
Output Specification
Output Voltage Line Voltage: 380×(1±1%)AC or Phase Voltage: 220×(1±1%)AC
Output PF 0.9
Output Voltage Regulation 380Vac±1%(Static Load); 380Vac±2%(50-0% Sudden Change); 380Vac±3%(100-0% Sudden Change)
Voltage Dynamic Response ±5%,(0~100% Sudden Change)
Voltage Dynamic Response Tim <5ms
Synchronization Range ±5%
Output Freq ±0.02% (BAT Mode)
THD < 1%(Linear Full Load), < 3% (Non-Linear Full Load)
3 Phase Unbalanced Allow 3 Phase 100% Unbalanced
Output Volt. Unbalanced ≤1% (Balanced Load), ≤2% (50% Balanced Load)
Input/Output Phase Swift ≤1°(Balanced Load), ≤2°(50% Balanced Load)
Frequency Tracking Range 45-65Hz
Output Waveform Pure Sine Wave
Overload With output PF 0.9, 105%: Long time Operation,110%: 1 Hour,125%: 10 Mins,150%:1 Min
Crest Ratio 3∶1
Short-Circuit Circuit Auto-Protection, Bypass Switch Tripping
Output Abnormal INV. Output Auto-Locked Protection
Bypass Specification
Static Bypass Transfer Time 0ms
Static Bypass Range 380/400/415Vac(±10%,±15%,±20% Selectable)3 Phase+N(3 Phase+N+PE)
Frequency Range 50/60Hz±10%
Bypass -> INV Transfer Time 2ms
Bypass Overload Ability 200%: 5 Mins; 1000%:10 Seconds
Manual Maintenance Bypass Available
Battery Specification
Type Sealed Lead Acid Maintenance Free
Std. Model Rated Volts/Units 12V,384Vdc/32 Units
Float Charge Voltage Equalized Charge, Float Charge, Intelligent Battery Management
BAT Low Shutdown Protection
Communication Specification
Communication Port RS232/SNMP/485/Dry Contact(Optional Accessory)
Remote Software Multi-functional Monitoring System, Online and BAT Mode Status, BAT Fault, Remote Control
Physical Parameters
Size mm(D) 855 855 855 855 955
Size mm(H) 1900 1900 1900 1900 1900
Size mm(W) 6 pulse 1245 1640 2265 -- --
Size mm(W) 12 pulse 1770 2265 2265 2615 2865
Net Weight Kg(6 pulse) 1075 1580 2105 -- --
Net Weight Kg(12 pulse) 1685 2090 2500 2850 3130

Note: Specifications are subject to change without further notice.