HomeProductsInverter Compressor Room Cooling Precision Air Conditioning
  • Inverter Compressor Room Cooling Precision Air Conditioning
  • Room Cooling Precision Air Conditioning Units
  • Room Cooling Precision Air Conditioning Units
  • Room Cooling Precision Air Conditioning Units
  • Room Cooling Precision Air Conditioning Units
  • Room Cooling Precision Air Conditioning Units
  • Inverter Compressor Room Cooling Precision Air Conditioning
  • Room Cooling Precision Air Conditioning Units
  • Inverter Compressor Room Cooling Precision Air Conditioning
  • Room Cooling Precision Air Conditioning Units
  • Room Cooling Precision Air Conditioning Units
  • Room Cooling Precision Air Conditioning Units
  • Room Cooling Precision Air Conditioning Units
  • Room Cooling Precision Air Conditioning Units
  • Inverter Compressor Room Cooling Precision Air Conditioning
  • Room Cooling Precision Air Conditioning Units

Inverter Compressor Room Cooling Precision Air Conditioning

7.5kW - 122.9kW ; 2250 - 27100m³/h
Overviews
The air-cooled room-level inverter compressor precision air conditioner unit adopts a modular design and is suitable for integrated temperature control solutions in places such as data centers, base stations, battery rooms and equipment rooms.
Air Flow Front / Side / Down
Refrigerant R410A
Fan Type ZIEHL-ABEGG EC Fan
Compressor Panasonic Inverter Compressor
  • Features

  • Specifications

  • Applications

  • Download

Room Cooling DX Cooled Series

Precise Climate Control
Datacool units come with a constant temperature and humidity function. They achieve remarkable accuracy, with temperature control within ±1℃ and relative humidity within ±5%. This ensures a stable environment for sensitive equipment.
Intelligent Connectivity
Equipped with an RS 485 standard interface, Datacool systems are Modbus-protocol-compatible. This enables seamless integration with dynamic environment monitoring platforms such as DCIM, BMS, and remote monitoring systems, facilitating real – time data access and control.
Flexible Cooling Capacity
Available in a wide capacity range from 7.5 KW to 122.9 KW, Datacool offers various configurations. These include single – and dual – circuit indoor units, as well as single – and dual – circuit condensers, catering to different cooling load requirements.
High Reliability
All Datacool products strictly comply with CE and IEC standards. They incorporate high – quality, certified components and undergo strict factory testing and commissioning before delivery, ensuring long – term reliability.
Adaptable Design
With multiple air – discharge options like downflow and upflow, Datacool units can be installed in different spaces. They feature multiple monitoring interfaces and are suitable for various ambient temperatures, with optional low – temperature kits available. Customized designs can also be provided to meet specific needs.
Energy – Efficient Operation
Datacool products are designed for energy efficiency. They use efficient DC inverter scroll compressors and EC fans, which allow for continuous airflow adjustment. The controller optimizes cooling efficiency, while the electrode humidifier ensures precise humidity control. A precision electronic expansion valve enables accurate cooling control, reducing energy consumption.

Read More

Model Configuration:

RC Unit type Room cooling
MA Structural form Standard construction/Modular structure
30 Nominal cooling capacity 30KW
U/D Upward air supply and forward air return Downdraft and updraft

 

Upflow Unit Downflow Unit W-007FA W-007DA W-012FA W-012DA W-017FA W-017DA W-020FA W-020DA W-025FA W-025DA
Cooling Capacity –kW 7.5 12.5 17.5 21.2 27.5
Sensible Capacity –kW 6.8 11.3 15.9 19.1 25
SHR-% 90.7 90.4 90.9 90.1 90.9
Air Volume -m3/h 2250 2850 5000 6200 6700
Fan Type AC / EC AC / EC AC / EC AC / EC AC / EC
Heating Capacity-kW 3 4 6 6 6
Heating Type PTC PTC PTC PTC PTC
Humidification Capacity -kg/h 2.5 4 4.5 4.5 5
Humidifier Type Electrode Electrode Electrode Electrode Electrode
Filter Rating G3 G3 G4 G4 G4
Weight -kg 128 178 300 318 338
Width -mm 550 650 750 750 850
Depth -mm 450 550 700 700 700
Height -mm 1750 1850 1900 1900 1900
Power Input 1) 208-240V
/50Hz|60Hz
/1Ph|2Ph
380-415V
/50Hz|60Hz
/3Ph
380-415V
/50Hz|60Hz
/3Ph
380-415V
/50Hz|60Hz
/3Ph
380-415V
/50Hz|60Hz
/3Ph
FLA -A 1)cooling 16.5 13.1 14.3 19.4 23.1
FLA -A 1)with heating/hum. 30.2 19.2 23.4 28.5 32.2
Power Input 2) - 200-230V/60Hz/3Ph 200-230V/60Hz/3Ph 200-230V/60Hz/3Ph 200-230V/60Hz/3Ph
FLA -A 2)cooling - 23.9 26.2 35.4 42.2
FLA -A 2)with heating/hum. - 35.1 42.9 52.1 58.1
Power Input 3) - 460V/60Hz/3Ph 460V/60Hz/3Ph 460V/60Hz/3Ph 460V/60Hz/3Ph
FLA -A 3)cooling - 10.8 11.8 16.0 19.1
FLA -A 3)with heating/hum. - 15.8 19.3 23.5 26.6
Ref. Pipe Connection –mm 10/12 12/16 16/16 16/16 16/22
Drain Connection –mm 20 20 20 20 20
Water In Connection 3/4"G 3/4"G 3/4"G 3/4"G 3/4"G
Single/Dual System Single Single Single Single Single
Refrigerant Type R410A R410A R410A R410A R410A
Standard Outdoor          
Unit Model KSF12 KSF18 KSF24 KSF24 KSF32
Unit Numbers 1 1 1 1 1

Notes:

1. Capacity based on 24℃/50%RH return air conditions, and 45℃ condensing temperature.
2. The standard ESP 20Pa. Higher application shall refer to technical department for confirmation.
3. FLA of indoor unit includes FLA of outdoor unit, and outdoor unit power connected from indoor unit.
4. Standard air-cooled outdoor unit operating temperature range -15℃ above, optional operating temperature range of the components -35℃ with low temperature kit.

Upflow Unit Downflow Unit SA30/SW30 U/D SA35/SW35 U/D SA40/SW40 U/D SA50/SW50 U/D DA45/DW45 U/D DA55/DW55 U/D DA65/DW65 U/D DA70/DW70 U/D DA80/DW80 U/D DA90/DW90 U/D DA100/DW100 U/D DA110/DW110 U/D DA120/DW120 U/D
Cooling Capacity - kW 32.5 37.7 41.8 50.0 43.5 53.1 65.1 71.1 83.6 92.1 100.9 110.9 122.9
Sensible Capacity - kW 29.3 34.0 38.1 45.0 39.2 47.8 58.8 64.0 75.3 83.6 91.1 97.1 105.2
SHR-% 90.2 90.2 91.1 90.0 90.1 90.2 90.3 90.0 90.1 90.8 90.2 87.6 85.6
Air Volume -m3/h 8325 8620 10500 12400 10500 12400 16650 17240 21000 22600 24800 26200 27100
Fan Type EC EC EC EC EC EC EC EC EC EC EC EC EC
Heating Capacity - kW 6 6 9 9 9 9 9 9 12 12 12 12 12
Heating Type PTC PTC PTC PTC PTC PTC PTC PTC PTC PTC PTC PTC PTC
Hum. Capacity -kg/h 8 8 10 10 10 10 10 10 12 12 12 12 12
Humidifier Type Electrode Electrode Electrode Electrode Electrode Electrode Electrode Electrode Electrode Electrode Electrode Electrode Electrode
Filter Rating G4 G4 G4 G4 G4 G4 G4 G4 G4 G4 G4 G4 G4
Weight -kg 433 438 468 528 478 568 688 718 788 866 888 902 930
Width -mm 1126 1126 1326 1326 1326 1326 1826 1826 2226 2226 2226 2226 2226
Depth -mm 990 990 990 990 990 990 990 990 990 990 990 990 990
Height -mm 1975 1975 1975 1975 1975 1975 1975 1975 1975 1975 1975 1975 1975
Power Input 1) 380-415V
/50Hz|60Hz
/3Ph
380-415V
/50Hz|60Hz
/3Ph
380-415V
/50Hz|60Hz
/3Ph
380-415V
/50Hz|60Hz
/3Ph
380-415V
/50Hz|60Hz
/3Ph
380-415V
/50Hz|60Hz
/3Ph
380-415V
/50Hz|60Hz
/3Ph
380-415V
/50Hz|60Hz
/3Ph
380-415V
/50Hz|60Hz
/3Ph
380-415V
/50Hz|60Hz
/3Ph
380-415V
/50Hz|60Hz
/3Ph
380-415V
/50Hz|60Hz
/3Ph
380-415V
/50Hz|60Hz
/3Ph
FLA -A 1) 35.5 36.3 46.0 49.6 48.2 53.8 66.4 67.2 83.0 86.6 90.2 93.8 97.2
Power Input 2) 460V
/60Hz
/3Ph
460V
/60Hz
/3Ph
460V
/60Hz
/3Ph
460V
/60Hz
/3Ph
460V
/60Hz
/3Ph
460V
/60Hz
/3Ph
460V
/60Hz
/3Ph
460V
/60Hz
/3Ph
460V
/60Hz
/3Ph
460V
/60Hz
/3Ph
460V
/60Hz
/3Ph
460V
/60Hz
/3Ph
460V
/60Hz
/3Ph
FLA -A 2) 29.3 30.0 38.0 41.0 39.8 44.5 54.9 55.5 68.6 71.5 74.5 77.4 80.3
Power Input 3) 208-230V
/60Hz
/3Ph
208-230V
/60Hz
/3Ph
208-230V
/60Hz
/3Ph
208-230V
/60Hz
/3Ph
208-230V
/60Hz
/3Ph
208-230V
/60Hz
/3Ph
208-230V
/60Hz
/3Ph
208-230V
/60Hz
/3Ph
208-230V
/60Hz
/3Ph
208-230V
/60Hz
/3Ph
208-230V
/60Hz
/3Ph
208-230V
/60Hz
/3Ph
208-230V
/60Hz
/3Ph
FLA -A 3) 64.9 66.4 84.0 90.6 88.1 98.3 121.3 122.8 151.7 158.2 164.8 171.3 177.5
Pipe Connection -mm 16/22 16/22 16/22 16/22 16/22 16/22 16/22 16/22 16/22 16/22 16/22 16/22 16/22
Drain Connection -mm 20 20 20 20 20 20 20 20 20 20 20 20 20
Water In Connection 3/4"G 3/4"G 3/4"G 3/4"G 3/4"G 3/4"G 3/4"G 3/4"G 3/4"G 3/4"G 3/4"G 3/4"G 3/4"G
Single/Dual System Single Single Single Single Dual Dual Dual Dual Dual Dual Dual Dual Dual
Refrigerant R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A
Standard Outdoor                          
Unit Model KSF38 KSF52 KSF52 KSF62 KSF32 KSF32 KSF42 KSF52 KSF52 KSF62 KSF62 KSF70 KSF76
Unit Numbers 1 1 1 1 2 2 2 2 2 2 2 2 2
Condenser Water Side                          
Water Flow –m3/h 7.24 7.96 9.1 10.91 4.88*2 5.41*2 7.24*2 7.96*2 9.1*2 9.53*2 10.91*2 11.96*2 13.36*2
Pressure Drop -kPa 53 50.1 50.8 52.2 48.3 51.3 52.6 50.1 50.8 50.4 52.2 50.3 51.7
Water Piping -mm 32 32 32 42 28 28 32 32 32 32 42 42 42

Notes:
1. Capacity based on 24℃/50%RH return air conditions, and 45℃ condensing temperature.
2. The standard ESP 20Pa. Higher application shall refer to technical department for confirmation.
3. FLA of indoor unit includes FLA of outdoor unit, and outdoor unit power connected from indoor unit.
4. Standard air-cooled outdoor unit operating temperature range-15℃ above, optional operating temperature range of the components -35℃ with low temperature kit.

Read More

- Computer room and data center

- Switch room and mobile center station in telecommunication

- High-tech environment and lab

- Industrial automation control room and precision manufacturing workshop.

- Standard test room and calibration center

- UPS and battery room

- Test room in the hospital

- Biochemical culture room

Room Cooling Precision Air Conditioning Units Application

Room Cooling Precision Air Conditioning Units Application

Read More
Read More

Contact Us

Reach Out for Product and Technical Support

请在浏览器中启用 JavaScript 来完成此表单。
WhatsApp

Leave a message!

Leave a message!

请在浏览器中启用 JavaScript 来完成此表单。

Open a conversation in WhatsApp?

Cancel OK