HomeProductsRackmount Static Transfer Switches for Seamless Power Switching
  • Rackmount Static Transfer Switches for Seamless Power Switching
  • Rackmount Static Transfer Switches for Seamless Power Switching

Rackmount Static Transfer Switches for Seamless Power Switching

Standard capacity: 3.5kW - 528kW
Overviews
STS, a static transfer switch, is an automatic two-power-source switching system. Normally, when the main power is within the normal voltage range, the load stays connected to it. STS uses a break-before-make switching method to achieve uninterrupted switching between power sources.
MSTS, a Multiple Spot Temperature Sensor Static Transfer Switch, is a rapid load transfer switch with a minimum transfer time of 3.2ms, suitable for both in-phase and out-of-phase conditions. It can be connected in multiple sets to form an n+1=1 output for enhanced power supply safety.
The RSTS series of STS is designed for A-level computer rooms. It's a high-performance, cost-effective, second-generation rapid transfer switch with new digital technology and a delayed topology for accurate transfer. It offers high protection, better safety and reliability, a user-friendly LCD interface, and RS232 communication for PC connection to monitor its status, adhering to the "Safety First" principle.
  • Features

  • Specifications

  • Applications

  • Download

• High reliability: Ensure that post electric equipment is at safe and green power consumption environment. Two-level transfer design, high-speed MCU control, real high-speed transfer system; With elements of international-level quality and high-level production and management, we provide you with reliable power protection.
• Super adaptability: This series of product is suitable for in-phase, out-of-phase, shared neutral line and unshared neutral line electric power environment. It can ensure safe power supply for post electric equipment to realize post green electric power environment; Any combination is available for the system: commercial powercommercial power, commercial power-UPS, UPS-UPS, commercial power-voltage stabilizer and voltage stabilizer-UPS.
• High synchronism: Perfect transfer of load. This series of product adopts synchro-control technology and high sampling module to ensure synchronism in transfer.
• Rapid load transfer: MSTS can realize fastest load transfer (3.2ms) in in-phase and out-of-phase environment.
• Power supply priority: MSTS can be self-set by users.
• Protection function: Output current over-limit protection 110%, impact resistance 4:1, input over-current and lightning protection.
• Friendly human-machine interface: MSTS provides dynamic LED operating state display. LCD provides electric quantity parameter and equipment running state display.
• Failure alarm: When faults occur on environmental electric quantity and output electric quantity, the equipment will automatically give sound-light alarm and will automatically shutdown 90’s later.
• Multifunctional interface: This series of product has PC connection interface (RS232) and dry contact interface.
• Reliable output connection: Standard IEC 320 C13, C19 output interface, convenient for connection with socket.

Read More

MSTS-Series Characteristics Main technical parameters:

Model MSTS-16A MSTS-25A MSTS-30A
Standard capacity 3.5KW 5.5KW 6.6KW
Rated current 16A 25A 30A
Transfer time ≤ 6ms
Output interface IEC C13, C19 IEC C19 IEC C19
Priority Self-set
Input M1-way input voltage range 200VAC-240VAC ±5V
M2-way input voltage range 200VAC-240VAC ±5V
Input frequency range 50HZ-60HZ
Electric power environment In-phase and out-of-phase
Output Output voltage range 200VAC-240VAC ±5V
Output over-current 1.1
Output efficiency ≥ 98%
Management State display LCD electric quantity parameter display, LED state display
Interface management RS232 interface/ dry contact interface
Software X
Protection Electric surge protection Input M1/input M2
Communication surge protection RS232 interface/ dry contact interface
Over-load short-circuit protection Over-current device, short-circuit protector
Certification Design and production IS09001:2000
Safety certification EN5009-2,IEC60950
Electromagnetic compatibility EN50091-2, EN61000-3-2, EN61000-4-2/-3/-4
Environment Ambient temperature 0℃ -40℃
Ambient humidity 10%-90%
Physical feature Body size (W*D*HMM) 482*250*44
Package size (W*D*HMM) 540*360*110

 

RSTS-Series Characteristics Main technical parameters:

Model RSTS-1125A RSTS-1132A RSTS-1140A RSTS-1163A RSTS-11100A
Standard capacity 5.5KW 7KW 8.8KW 13.8KW 22KW
Rated current 25A 32A 40A 63A 100A
Transfer time ≤ 6ms
Output interface Connector bar
Priority Self-set
Input M1-way input voltage range 200VAC-240VAC ±5V
M2-way input voltage range 200VAC-240VAC ±5V
Input frequency range 50HZ-60HZ
Electric power environment In-phase and out-of-phase
Output Output voltage range 200VAC-240VAC ±5V
Output over-current 1.1
Output efficiency ≥ 98%
Management State display LCD electric quantity parameter display, LED state display
Interface management RS232 interface/ dry contact interface
Software X
Protection Electric surge protection Input M1/input M2
Communication surge protection RS232 interface/dry contact interface
Over-load short-circuit protection Over-current device, short-circuit protector
Certification Design and production IS09001:2000
Safety certification EN5009-2, IEC60950
Electromagnetic compatibility EN50091-2, EN61000-3-2, EN61000-4-2/-3/-4
Environment Ambient temperature 0℃-40℃
Ambient humidity 10%-90%
Physical
feature
Body size (W*D*HMM) 482*400*133
Package size (W*D*HMM) 550*520*230

 

RSTS-Series  three-phase Characteristics   Main technical parameters:

Model RSTS-3325A RSTS-3332A RSTS-3340A RSTS-3363A RSTS-33100A
Standard capacity 16.5KW 21KW 26KW 41.5KW 66KW
Rated current 25Afor each
phase
32Afor each
phase
40Afor each
phase
63Afor each
phase
100for each
phase
Transfer time Average ≤ 6ms
Output interface Copper busbar
Priority Self-set
Input M1-way input voltage range 380V ±10%
M2-way input voltage range 380V ±10%
Input frequency range 50HZ
Electric power environment In-phase and out-of-phase
Output Output voltage range 380V ±10%
Output over-current 1.1
Output efficiency ≥ 98%
Management State display LCD electric quantity parameter display, LED state display
Interface management Rs232 interface
Software Option OUXP-0.1V
Protection Electric surge protection Input M1/input M2
Communication surge protection Rs232 interface
Over-load short-circuit protection Over-current device, short-circuit protector
Environment Ambient temperature 0℃ -40℃
Ambient humidity 10%-90%
Physical feature Body size (W*D*HMM) 380*600*800
Package size (W*D*HMM) 400*650*850

 

Model RSTS-33160A RSTS-33200A RSTS-33250A RSTS-33400A RSTS-33600A RSTS-33800A
Standard capacity 105.6KW 132KW 165KW 264KW 396KW 528KW
Rated current 160A for each
phase
200A for each
phase
250A for each
phase
400A for each
phase
600A for each
phase
800A for each
phase
Transfer time Average ≤ 6ms
Output interface Copper busbar
Priority Self-set
Input M1-way input voltage range 380V ±10%
M2-way input voltage range 380V ±10%
Input frequency range 50HZ
Electric power environment In-phase and out-of-phase
Output Output voltage range 380V ±10%
Output over-current 1.1
Output efficiency ≥ 98%
Management State display LCD electric quantity parameter display, LED state display
Interface management Rs232 interface
Software Option OUXP-0.1V
Protection Electric surge protection Input M1/input M2
Communication surge protection Rs232 interface
Over-load short-circuit
protection
Over-current device, short-circuit protector
Environment Ambient temperature 0℃ -40℃
Ambient humidity 10%-90%
Physical feature Body size (W*D*H) 1000*600*1800
Package size (W*D*H) 1050*650*1850