Room Cooling Precision Air Conditioning Units
Cooling Capacity: 5.5kW – 122.9kW
Features
Specifications
Applications
Download
-
• Safe and Reliable
With 20 years of experience in the research, development and manufacturing of precision air conditioners, the whole process from R&D design, component configuration to production manufacturing and inspection testing is completely under digital control, constantly striving for excellence.Key components such as compressors, fans and controllers all adopt top brands in the industry, with a Mean Time Between Failures (MTBF) of no less than 100,000 hours.
The expert-level precision air conditioner control system comes standard with a 7-inch touch screen and a graphical interface. It can display parameters such as temperature and humidity in the form of curves, supports remote monitoring and management, and has the function of automatic startup upon power restoration.
• Low-Carbon and Energy-Saving
There are options for fixed-frequency and variable-frequency refrigeration systems available, with remarkable energy-saving effects.The indoor fan adopts a backward-inclined centrifugal EC fan, which can automatically and steplessly adjust the air volume according to the refrigeration requirements, achieving high efficiency, energy conservation and low noise.
A large-area V-shaped evaporator is adopted to optimize the air flow organization and enable efficient heat exchange.
• Flexible Application
It supports top air supply, bottom air supply (with the fan sunk), front-top air supply and duct air supply.The electric control box is installed with drawer-type slide rails, facilitating service and maintenance.
Optional accessories such as low-temperature components, pipeline extension components, condensate pumps, water leakage monitoring devices, dual power supplies and V-shaped condensers are available to support special application scenarios.
• Support for Customization
It offers flexible and comprehensive customization services, supporting customized unit performance, external dimensions and appearance design, etc.Read More -
Upflow Unit Downflow Unit W-005FA W-005DA W-007FA W-007DA W-012FA W-012DA W-017FA W-017DA W-020FA W-020DA W-025FA W-025DA Cooling Capacity –kW 5.5 7.5 12.5 17.5 21.2 27.5 Sensible Capacity –kW 5.2 6.8 11.3 15.9 19.1 25 SHR-% 94.5 90.7 90.4 90.9 90.1 90.9 Air Volume -m3/h 2000 2250 2850 5000 6200 6700 Fan Type AC / EC AC / EC AC / EC AC / EC AC / EC AC / EC Heating Capacity-kW 3 3 4 6 6 6 Heating Type PTC PTC PTC PTC PTC PTC Humidification Capacity -kg/h 2.5 2.5 4 4.5 4.5 5 Humidifier Type Electrode Electrode Electrode Electrode Electrode Electrode Filter Rating G3 G3 G3 G4 G4 G4 Weight -kg 118 128 178 300 318 338 Width -mm 550 550 650 750 750 850 Depth -mm 450 450 550 700 700 700 Height -mm 1750 1750 1850 1900 1900 1900 Power Input 1) 208-240V
/50Hz|60Hz
/1Ph|2Ph208-240V
/50Hz|60Hz
/1Ph|2Ph380-415V
/50Hz|60Hz
/3Ph380-415V
/50Hz|60Hz
/3Ph380-415V
/50Hz|60Hz
/3Ph380-415V
/50Hz|60Hz
/3PhFLA -A 1)cooling 14.5 16.5 13.1 14.3 19.4 23.1 FLA -A 1)with heating/hum. 28.2 30.2 19.2 23.4 28.5 32.2 Power Input 2) - - 200-230V/60Hz/3Ph 200-230V/60Hz/3Ph 200-230V/60Hz/3Ph 200-230V/60Hz/3Ph FLA -A 2)cooling - - 23.9 26.2 35.4 42.2 FLA -A 2)with heating/hum. - - 35.1 42.9 52.1 58.1 Power Input 3) - - 460V/60Hz/3Ph 460V/60Hz/3Ph 460V/60Hz/3Ph 460V/60Hz/3Ph FLA -A 3)cooling - - 10.8 11.8 16.0 19.1 FLA -A 3)with heating/hum. - - 15.8 19.3 23.5 26.6 Ref. Pipe Connection –mm 10/12 10/12 12/16 16/16 16/16 16/22 Drain Connection –mm 20 20 20 20 20 20 Water In Connection 3/4"G 3/4"G 3/4"G 3/4"G 3/4"G 3/4"G Single/Dual System Single Single Single Single Single Single Refrigerant Type R410A R410A R410A R410A R410A R410A Standard Outdoor Unit Model KSF08 KSF12 KSF18 KSF24 KSF24 KSF32 Unit Numbers 1 1 1 1 1 1 Notes:
1. Capacity based on 24℃/50%RH return air conditions, and 45℃ condensing temperature.
2. The standard ESP 20Pa. Higher application shall refer to technical department for confirmation.
3. FLA of indoor unit includes FLA of outdoor unit, and outdoor unit power connected from indoor unit.
4. Standard air-cooled outdoor unit operating temperature range-15℃ above, optional operating temperature range of the components -35℃ with low temperature kit.Upflow Unit Downflow Unit W-030UA W-030DA W-035UA W-035DA W-040UA W-040DA W-050UA W-050DA W-045UA W-045DA W-055UA W-055DA W-065UA W-065DA W-070UA W-070DA W-080UA W-080DA W-090UA W-090DA W-100UA W-100DA W-110UA W-110DA W-120UA W-120DA Cooling Capacity - kW 32.5 37.7 41.8 50.0 43.5 53.1 65.1 71.1 83.6 92.1 100.9 110.9 122.9 Sensible Capacity - kW 29.3 34.0 38.1 45.0 39.2 47.8 58.8 64.0 75.3 83.6 91.1 97.1 105.2 SHR-% 90.2 90.2 91.1 90.0 90.1 90.2 90.3 90.0 90.1 90.8 90.2 87.6 85.6 Air Volume -m3/h 8325 8620 10500 12400 10500 12400 16650 17240 21000 22600 24800 26200 27100 Fan Type EC EC EC EC EC EC EC EC EC EC EC EC EC Heating Capacity - kW 6 6 9 9 9 9 9 9 12 12 12 12 12 Heating Type PTC PTC PTC PTC PTC PTC PTC PTC PTC PTC PTC PTC PTC Hum. Capacity -kg/h 8 8 10 10 10 10 10 10 12 12 12 12 12 Humidifier Type Electrode Electrode Electrode Electrode Electrode Electrode Electrode Electrode Electrode Electrode Electrode Electrode Electrode Filter Rating G4 G4 G4 G4 G4 G4 G4 G4 G4 G4 G4 G4 G4 Weight -kg 433 438 468 528 478 568 688 718 788 866 888 902 930 Width -mm 1126 1126 1326 1326 1326 1326 1826 1826 2226 2226 2226 2226 2226 Depth -mm 990 990 990 990 990 990 990 990 990 990 990 990 990 Height -mm 1975 1975 1975 1975 1975 1975 1975 1975 1975 1975 1975 1975 1975 Power Input 1) 380-415V
/50Hz|60Hz
/3Ph380-415V
/50Hz|60Hz
/3Ph380-415V
/50Hz|60Hz
/3Ph380-415V
/50Hz|60Hz
/3Ph380-415V
/50Hz|60Hz
/3Ph380-415V
/50Hz|60Hz
/3Ph380-415V
/50Hz|60Hz
/3Ph380-415V
/50Hz|60Hz
/3Ph380-415V
/50Hz|60Hz
/3Ph380-415V
/50Hz|60Hz
/3Ph380-415V
/50Hz|60Hz
/3Ph380-415V
/50Hz|60Hz
/3Ph380-415V
/50Hz|60Hz
/3PhFLA -A 1) 35.5 36.3 46.0 49.6 48.2 53.8 66.4 67.2 83.0 86.6 90.2 93.8 97.2 Power Input 2) 460V
/60Hz
/3Ph460V
/60Hz
/3Ph460V
/60Hz
/3Ph460V
/60Hz
/3Ph460V
/60Hz
/3Ph460V
/60Hz
/3Ph460V
/60Hz
/3Ph460V
/60Hz
/3Ph460V
/60Hz
/3Ph460V
/60Hz
/3Ph460V
/60Hz
/3Ph460V
/60Hz
/3Ph460V
/60Hz
/3PhFLA -A 2) 29.3 30.0 38.0 41.0 39.8 44.5 54.9 55.5 68.6 71.5 74.5 77.4 80.3 Power Input 3) 208-230V
/60Hz
/3Ph208-230V
/60Hz
/3Ph208-230V
/60Hz
/3Ph208-230V
/60Hz
/3Ph208-230V
/60Hz
/3Ph208-230V
/60Hz
/3Ph208-230V
/60Hz
/3Ph208-230V
/60Hz
/3Ph208-230V
/60Hz
/3Ph208-230V
/60Hz
/3Ph208-230V
/60Hz
/3Ph208-230V
/60Hz
/3Ph208-230V
/60Hz
/3PhFLA -A 3) 64.9 66.4 84.0 90.6 88.1 98.3 121.3 122.8 151.7 158.2 164.8 171.3 177.5 Pipe Connection -mm 16/22 16/22 16/22 16/22 16/22 16/22 16/22 16/22 16/22 16/22 16/22 16/22 16/22 Drain Connection -mm 20 20 20 20 20 20 20 20 20 20 20 20 20 Water In Connection 3/4"G 3/4"G 3/4"G 3/4"G 3/4"G 3/4"G 3/4"G 3/4"G 3/4"G 3/4"G 3/4"G 3/4"G 3/4"G Single/Dual System Single Single Single Single Dual Dual Dual Dual Dual Dual Dual Dual Dual Refrigerant R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A Standard Outdoor Unit Model KSF38 KSF52 KSF52 KSF62 KSF32 KSF32 KSF42 KSF52 KSF52 KSF62 KSF62 KSF70 KSF76 Unit Numbers 1 1 1 1 2 2 2 2 2 2 2 2 2 Notes:
1, Capacity based on 24℃/50%RH return air conditions, and 45℃ condensing temperature.
2, The standard ESP 20Pa. Higher application shall refer to technical department for confirmation.
3, FLA of indoor unit includes FLA of outdoor unit, and outdoor unit power connected from indoor unit.
4, Standard air-cooled outdoor unit operating temperature range-15℃ above, optional operating temperature range of the components -35℃ with low temperature kit.Read More -