HomeProductsUPS Power SupplyHigh-Frequency UPSTower 3-Phase Input 3-Phase Output 30-200kVA High Frequency UPS
  • High-Frequency UPS Tower 30-to-200kva
  • High-Frequency UPS Tower 30-to-200kva

Tower 3-Phase Input 3-Phase Output 30-200kVA High Frequency UPS

Power Factor: 1 ; 30 - 200kVA
Overviews
The 30 - 200KVA tower UPS is a powerhouse for critical applications. It features a scalable power capacity, catering to diverse needs. The tower design is beautiful, space saving and easy to install. Using digital control technology, the output voltage precision is high to ensure the stable operation of the load. Fast dynamic response, switch to battery power in milliseconds after mains failure, ensuring no service interruption. Rich communication interfaces to achieve remote monitoring and management, convenient operation and maintenance personnel to know the status at any time.
  • Features

  • Specifications

  • Applications

  • Download

Double conversion online topology design.
Supports parallel function.
Ultra-wide mains input range (110V – 300V).
Output power factor up to 1.
LCD display.
With emergency power off (EPO) function.
High adaptability to environment.
With SNMP + USB + RS-232 multi-monitoring functions.
Optional intelligent battery monitoring module.

Read More
Model/HF33 30 KVA 60 KVA 100 KVA 120 KVA 180 KVA 200 KVA
Phase 3phase in, 3phase out
Capacity 30KVA/30KW 60KVA/60KW 100KVA/100KW 120KVA/120KW 180KVA/180KW 200KVA/200KW
Parallel quantity 6
Enter
Rated voltage 3×380/400/415VAC(3PH+N)
Voltage range 110-300VAC·50% load; 176-276 VAC·100% load
Frequency range 40 ~ 70 Hz
Power factor ≥0.99 @100% load
Input current harmonic component (THDI) <3% at full linear load
Output
Rated voltage 3×360*/380/400/415 VAC(3 phase+N)
Voltage stabilization accuracy (battery mode) ±1%
Frequency range (synchronous correction range) 46~54Hz or 56~64Hz
Frequency range (battery mode) 50/60Hz±1%
Current wave front ratio 3:1 (maximum)
Harmonic distortion ≦1%THD(linear load);≦3%THD(non-linear load)
Conversion time Mains mode to battery mode none
Inverter to bypass none
Waveform (battery mode) pure sine wave
Overload capacity 100-110% 60 minutes·111-125% 10 minutes·126%-150% 1 minute; >150% 400ms
Bypass
Rated voltage 3×380/400/415VAC(3PH+N)
Voltage range -30%~+20% (adjustable)
Frequency range (synchronization range) 46 ~ 54Hz or 56 ~ 64Hz
Overload capacity >130% for 1 minute (default); continue working until circuit breaker protection (optional)
Efficiency
Communication pattern 96.0%
ECO mode 99.0%
battery mode 96.0%
Battery
Battery Type Match multiple battery boxes according to actual application
Battery quantity 32~40 (adjustable)
Maximum charging current 1A~12A·Adjustable 1A~20A·Adjustable 2A~40A·Adjustable 3A ~ 60A·Adjustable
Charging voltage ±13.65V*N(N=16~20)
Display instructions
7-inch color touch LCD panel UPS status · Load level · Battery level · Input/output voltage · Discharge timer and fault conditions
Physical properties
Dimensions, depth x width x height (mm) 815×300×1000 974×600×1600
Net weight (kg) 55 74 286 286 382 382
Usage Environment
Temperature and humidity 0-40°C; 0-95% relative humidity (non-condensing)
Altitude** 0~1500m when fully loaded
Noise Less than 65dB@1m Less than 75dB@1 meter
Display instructions
Smart RS-232/USB Supports Windows*2000/2003/XP/ Vista/2008 · Windows*7/8 · Linux and MAC
Optional SNMP Power management for SNMP managers and web browsers

*When the output voltage is set to 3×360VAC, the output capacity is derated to 90%.
*If the UPS is installed or used at an altitude higher than the maximum altitude; The output capacity is reduced by 1% for every 100m; Product specifications are subject to change without prior notice.

Read More

 

 

 