HomeProductsUPS Power SupplyHigh-Frequency UPSTower High Frequency 1-10kVA UPS
  • High-Frequency UPS Tower 1-to-10kva
  • High-Frequency UPS Tower 1-to-10kva

Tower High Frequency 1-10kVA UPS

Power Factor: 0.8 ; Single-Phase Grounding
Overviews
Tower high - frequency UPS (Uninterruptible Power Supply) is a reliable power backup solution designed to provide continuous and clean power to critical electrical equipment. It plays a vital role in various applications where power outages can cause significant disruptions or data loss.
  • Features

  • Specifications

  • Applications

  • Download

True online double conversion.
Microprocessor control ensures high reliability.
Input power factor correction function.
Output power factor up to 0.8.
Ultra-wide mains input range (110V – 300V).
Efficient frequency conversion mode.
Compatible with generator input.
Optional smart SNMP card can be perfectly monitored alone or with USB, RS232.
Easy operation and control through the display, and comprehensive display and monitoring of the UPS status.

Read More
Model SYT1K(S) SYT2K(S) SYT3K(S) SYT6K(S) SYT10K(S)
Phase Single-phase grounding
Capacity 1000VA/800W 2000VA/1600W 3000 VA/2400 W 6000VA/4800W 10000 VA/8000 W
Input
Input voltage 100/110/115/120/127VAC or 200/208/220/230/240VAC 208/220/230/240VAC
Voltage range 55-150 VAC or 110-300 VAC at 50% load 85-140VAC or 160-280VAC at 100% load 110-300 VAC at 50% load 176-300 VAC at 100% load
Frequency range 40 Hz ~70 Hz 46~54 Hz or 56~64 Hz
Power Factor ≧0.99@100% load
Output
Output voltage 100/110/115/120/127VAC or 200/208/220/230/240VAC 208/220/230/240VAC
Voltage regulation accuracy (battery mode) ±1%
Frequency range (synchronous correction range) 47~53 Hz or 57~63 Hz 46~54 Hz or 56~64 Hz
Frequency range (battery mode) 50 Hz ± 0.25 Hz or 60 Hz ± 0.3 Hz 50 Hz or 60 Hz ± 0.1 Hz
Crest Factor 3:1
Harmonic distortion ≦3%THD (linear load) ≤6%THD (non-linear load) ≦3%THD (linear load) ≤5%THD (nonlinear load)
Conversion time Mains power to battery zero
Inverter to bypass 4 ms (under standard conditions) none
Waveform (battery mode) pure sine wave
Efficiency
Mains power mode 88% 88% 90% 92% 93%
Battery mode 83% 85% 88% 90% 91%
Battery
Standard machine Battery model 12V/9Ah 12V/9Ah 12V/9Ah 12V/7Ah 12V/9Ah
Quantity 2 4 6 16 20 16 20
Standard charging time Charge to 90% in 4 hours Charge to 90% in 9 hours
Maximum charging current 1A 1A/2A
Charging voltage 27.4VDC±1% 54.7VDC±1% 82.1VDC±1% 218.4VDC±1% 273VDC±1% 218.4VDC±1% 273VDC±1%
Long lasting machine Battery model Depends on the applicant
Quantity 2 3 4 6 8 6 8 16~20(adjustable)
Maximum charging current 1A/2A/4A/6A(adjustable) 1A/2A/4A/6A (adjustable, 6A is only suitable for 16 batteries)
Charging voltage 27.4VDC±1%| 41.0VDC±1% 54.7VDC±1% 82.1VDC±1% 109.4VDC±1% 82.1VDC±1% 109.4VDC±1% 273 VDC±1% (based on 20 pcs)
Display
LCD Load size, battery capacity, mains mode, battery mode, bypass mode, fault indication
Warning sound
Battery mode Beeps every 4 seconds
Battery low One sound every 1 second
Overload One sound every 1 second
Fault Continuous beeping
Physical properties
Standard machine Dimensions, depth × width × height (mm) 282×145×220 397×145×220 421×190×318 369x190x688 442×190×688
Net weight (kg) 9.8 17 27.6 61 74 66 76
Long lasting machine Dimensions, depth × width × height (mm) 282×145×220 397×145×220 369×190×318 442×190×318
Net weight (kg) 4.1 6.8 7.4 12 16
Usage environment
Humidity 20-90%RH @0-40℃(no condensation) Relative humidity 0-95% and temperature 0-50℃ (no condensation) Relative humidity 0-95% and temperature 0-40℃ (no condensation)
Noise Less than 50dBA@1 meter Less than 55dBA@1 meter Less than 58dBA@1 meter
Control management
Smart RS-232/optional USB Support Windows2000/2003/XP/Vista/2008, Windows7/8, Linux and MAC
OptionalSNMP Power management supports SNMP management and network management

*When the 1-3KVA UPS is set to constant voltage and constant frequency mode, the output power will be derated by 80%. When the output voltage of the UPS is set to 100/200/208VAC, the output power will be derated by 80%. When the 6/10KVA UPS is set to constant voltage and constant frequency mode, the output power will be derated by 60%. When the output voltage of the UPS is set to 208VAC, the output power will be derated by 90%. **200/208/220/230/240VAC is only suitable for long-term machines (200VAC is only suitable for 1-3KVA). Current product specifications are subject to change without further notice.

Read More

 

 

 