Tower High Frequency 1-10kVA UPS
Features
Specifications
Applications
Download
-
• True online double conversion.
• Microprocessor control ensures high reliability.
• Input power factor correction function.
• Output power factor up to 0.8.
• Ultra-wide mains input range (110V – 300V).
• Efficient frequency conversion mode.
• Compatible with generator input.
• Optional smart SNMP card can be perfectly monitored alone or with USB, RS232.
• Easy operation and control through the display, and comprehensive display and monitoring of the UPS status.Read More -
Model SYT1K(S) SYT2K(S) SYT3K(S) SYT6K(S) SYT10K(S) Phase Single-phase grounding Capacity 1000VA/800W 2000VA/1600W 3000 VA/2400 W 6000VA/4800W 10000 VA/8000 W Input Input voltage 100/110/115/120/127VAC or 200/208/220/230/240VAC 208/220/230/240VAC Voltage range 55-150 VAC or 110-300 VAC at 50% load 85-140VAC or 160-280VAC at 100% load 110-300 VAC at 50% load 176-300 VAC at 100% load Frequency range 40 Hz ~70 Hz 46~54 Hz or 56~64 Hz Power Factor ≧0.99@100% load Output Output voltage 100/110/115/120/127VAC or 200/208/220/230/240VAC 208/220/230/240VAC Voltage regulation accuracy (battery mode) ±1% Frequency range (synchronous correction range) 47~53 Hz or 57~63 Hz 46~54 Hz or 56~64 Hz Frequency range (battery mode) 50 Hz ± 0.25 Hz or 60 Hz ± 0.3 Hz 50 Hz or 60 Hz ± 0.1 Hz Crest Factor 3:1 Harmonic distortion ≦3%THD (linear load) ≤6%THD (non-linear load) ≦3%THD (linear load) ≤5%THD (nonlinear load) Conversion time Mains power to battery zero Inverter to bypass 4 ms (under standard conditions) none Waveform (battery mode) pure sine wave Efficiency Mains power mode 88% 88% 90% 92% 93% Battery mode 83% 85% 88% 90% 91% Battery Standard machine Battery model 12V/9Ah 12V/9Ah 12V/9Ah 12V/7Ah 12V/9Ah Quantity 2 4 6 16 20 16 20 Standard charging time Charge to 90% in 4 hours Charge to 90% in 9 hours Maximum charging current 1A 1A/2A Charging voltage 27.4VDC±1% 54.7VDC±1% 82.1VDC±1% 218.4VDC±1% 273VDC±1% 218.4VDC±1% 273VDC±1% Long lasting machine Battery model Depends on the applicant Quantity 2 3 4 6 8 6 8 16~20(adjustable) Maximum charging current 1A/2A/4A/6A(adjustable) 1A/2A/4A/6A (adjustable, 6A is only suitable for 16 batteries) Charging voltage 27.4VDC±1%| 41.0VDC±1% 54.7VDC±1% 82.1VDC±1% 109.4VDC±1% 82.1VDC±1% 109.4VDC±1% 273 VDC±1% (based on 20 pcs) Display LCD Load size, battery capacity, mains mode, battery mode, bypass mode, fault indication Warning sound Battery mode Beeps every 4 seconds Battery low One sound every 1 second Overload One sound every 1 second Fault Continuous beeping Physical properties Standard machine Dimensions, depth × width × height (mm) 282×145×220 397×145×220 421×190×318 369x190x688 442×190×688 Net weight (kg) 9.8 17 27.6 61 74 66 76 Long lasting machine Dimensions, depth × width × height (mm) 282×145×220 397×145×220 369×190×318 442×190×318 Net weight (kg) 4.1 6.8 7.4 12 16 Usage environment Humidity 20-90%RH @0-40℃(no condensation) Relative humidity 0-95% and temperature 0-50℃ (no condensation) Relative humidity 0-95% and temperature 0-40℃ (no condensation) Noise Less than 50dBA@1 meter Less than 55dBA@1 meter Less than 58dBA@1 meter Control management Smart RS-232/optional USB Support Windows2000/2003/XP/Vista/2008, Windows7/8, Linux and MAC OptionalSNMP Power management supports SNMP management and network management *When the 1-3KVA UPS is set to constant voltage and constant frequency mode, the output power will be derated by 80%. When the output voltage of the UPS is set to 100/200/208VAC, the output power will be derated by 80%. When the 6/10KVA UPS is set to constant voltage and constant frequency mode, the output power will be derated by 60%. When the output voltage of the UPS is set to 208VAC, the output power will be derated by 90%. **200/208/220/230/240VAC is only suitable for long-term machines (200VAC is only suitable for 1-3KVA). Current product specifications are subject to change without further notice.
Read More -
Read More
-
Read More
Contact Us
24 hours online, to ensure your after-sales worry.