Capacity | 400kVA - 2000kVA |
Input Phase | 3P + N + PE |
Input Voltage | 380/400/415VAC (Line voltage), 220/230/240VAC (Phase voltage) |
Output Voltage | 380/400/415VAC (line voltage), 220/230/240V AC (phase voltage) |
Tower High Frequency 400-1000kVA 3-Phase UPS
Features
Specifications
Applications
Download
-
• Versatile Grid Compatibility for Power Quality Assurance
Supports power grid systems with voltages of 380/400/415V and frequencies of 50/60Hz. It offers high – quality power supply and reliable load protection, meeting the power demands of diverse scenarios.
• High-Efficiency and Energy-Saving Performance
The input power factor reaches as high as 0.99, while the input harmonic current is less than 3%. With an overall efficiency of up to 96%, it is highly efficient and energy-saving, effectively reducing operating costs.
• Precise Full-Digital Control
Utilizes DSP full-digital control technology to achieve full-digital management of power conversion processes such as rectification, inversion, charging, and discharging. This ensures stable operation and precise control.
• Wide-Range Adaptability and Flexible Compatibility
Features an ultra-wide input voltage and frequency range, enabling it to adapt to harsh power grid environments. It can also be flexibly connected to various fuel generators to guarantee continuous power supply.
• User-Friendly Interactive Interface
Equipped with a large LCD touch screen and a control keyboard, it provides a user-friendly interface with rich information display and convenient operation, enhancing the user experience.Read More -
Model SYT400 SYT500 SYT600 SYT1000 SYT1500 SYT2000 Capacity 400KVA /400KW 500KVA/500kW 600kVA/600kW 1000KVA/ 1000kW 1500KVA/1500KW 2000KVA/2000kW INPUT Input Method 3P + N + PE 3P + N + PE Input Voltage 380/400/415VAC (Line voltage) 380/400/415VAC (line voltage) 220/230/240VAC (phase voltage) Input Frequency - 50/60Hz Power Factor > 0.99 > 0.99 Current Distortion Rate THDi<3% (100% linear load) THDi<3% (100% linear load) Voltage Range 304-478VAC (Line voltage) full load; Linear derating of 304-228VAC (Line voltage) load from 100% to 75% 304-478VAC (line voltage) full load;
Linear derating of 304-228VAC (line voltage) load from 100% to 75%Frequency Range 40 - 70 Hz 40 - 70 Hz BATTERY Battery Voltage ± 240VDC (Adjustable for sections 32-44) ± 240VDC (Adjustable for sections 32-44) Charging Power 20% *Active power 20% *Active power Charging Voltage Accuracy ± 1% ± 1% BYPASS Rated Voltage 380/400/41 SVAC (Line voltage) - Bypass Voltage - 380/400/415VAC (Line voltage) 220/230/240VAC (Phase voltage) Voltage Range Default can be set to -20%~+15%; Upper limit+10%,+15%,+20%,+25%, lower limit: -10%, -15%, -20%, -30%, -40% Can be set, default -20% -+15%; Upper limit+10%,+15%,+20%,+25%; Lower limit -10%, -15%, -20%, -30%, -40% Frequency Range Can be set (± 1Hz, ± 3Hz, ± 5Hz) - Overload Capacity - 110%, long-term employment,101%<load<125%, not less than 5 minutes 125%<load<150%, not less than 1 minute,>150%, 1 second OUTPUT Rated Output Voltage 380/400/41 SVAC (Line voltage) 380/400/415VAC (line voltage); 220/230/240V AC (phase voltage) Rated Frequency 50 / 60 Hz 50 / 60 Hz Power Factor 1 1 Voltage Accuracy ± 1.0% ± 1.0% Frequency Tracking Range 50/60Hz ± 3Hz, (can be set to ± 0.5~5Hz) Can be set, ± 0.5Hz - ± 5Hz, default ± 3Hz Frequency Tracking Rate 0.1 Hz/s to 5 Hz/s, (Adjustable, default 2Hz/s) Can be set, 0.5Hz/s-3Hz/s, default 0.5Hz/s Frequency Accuracy 0.1% 0.1% Output Dynamic Response <5% (20% -80% -20% step load) <5% (20% -80% -20% step load) Dynamic Recovery Time <20ms (0% -100% -0% step load) <20ms (0% -100% -0% step load) Output total Harmonic Distortion(THDu) - <1% (linear load),<5% (non-linear load) Inverter Overload Capacity 110%, switch to bypass after 1 hour; 125%, switch to bypass after 10 minutes; 150%, switch to bypass after 1 minute 150%, Switch to bypass after 200ms 110%, switch to bypass after 1 hour; 125%, switch to bypass after 10 minutes; 150%, switch to bypass after 1 minute 150%, Switch to bypass after 200ms Three Phase Accuracy 120° ± 0.5° 120° ± 0.5° Voltage lmbalance ± 3% (100% unbalanced load) - Peak Ratio 3:1 3:1 SYSTEM Rated Output Voltage ≥ 97% ≥ 97% Battery Mode ≥ 97% ≥ 97% Display LCD+LED+10 inch color touch screen LCD+LED+10 inch color touch screen Safety Regulations IEC62040-1, IEC60950-1 IEC62040-1, IEC60950-1 EmS IEC62040-2; IEC61000-4-2(ESD); IEC61000-4-3(RS); IEC61000-4-4 (EFT); IEC61000-4-5 (Surge) IEC62040-2; IEC61000-4-2(ESD); IEC61000-4-3(RS); IEC61000-4-4 (EFT); IEC61000-4-5 (Surge) Protection Level IP20 IP20 Noise (1 meter) 72dB @ 100% load, 69dB@45 %Load 72dB @ 100% load, 69dB@45 %Load Working Temperature 0 - 40℃ 0-40 ℃ (working temperature) -25 ℃-70 ℃ (storage temperature) Relative Humidity 0-95% (No condensation) 0-95% (No condensation) Standard Configuration USB, RS232, RS485, Dry connection point card, battery cold start, dust screen USB, RS232, RS485, Dry connection point card, battery cold start, dust screen Options SNMP card, AS400 card, parallel component, lightning protection component LBS SNMP card, AS400 card, parallel component, lightning protection component LBS SIZE W * D * H mm 1200* 1000*2000 1200*1100*2000 2000*1100*2000 2800*1100*2000 3400*1100*2000 *Disclaimer: Our company's products will continue to innovate and optimize, which may result in a mismatch between promotional brochures and actual product updates.
Therefore, this document is for reference only and does not constitute any offer or commitment.Read More -
Read More
-
Read More
Contact Us
Reach Out for Product and Technical Support